63
Troubleshooting
FAILURE
No water | No function
Fitting triggers automatically
Water running time too long | too short
Fitting does not close | Fitting drips
Water flow too low
Outlet temperature too low
Outlet temperature only hot or cold
variations in temperature
Temperature setting sluggish | not possible - Cartridge in thermostat battery dirty or
CONTI Sanitärarmaturen GmbH | Hauptstraße 98 | 35435 Wettenberg | Deutschland | Tel. +49 641 98221 0 | Fax +49 641 98221 50 | info@conti.plus
www.conti.plus | Druckfehler und Irrtümer sowie technische und maßliche Änderungen vorbehalten. | Errors and technical changes remain reserved.
POSSIBLE CAUSE
- Water supply shut off
- No voltage
- Locking activated
- Scald protection activated
- Immersion sensor defective or connecti
on interrupted
- Clamping error due to moisture in the
connection distributor
- Contact faults due to moisture in plug
connections
- Solenoid valve defective
- Piezo button defective
- Bus device defective (CNX)
- Moisture in connectors
- Piezo button defective
- Hygiene flushing active (no error)
- Bus device defective (CNX)
- Water flow time not set correctly
- Water flow time not stored by the bus
device (CNX)
- Solenoid valve dirty or defective
- Filters | Sieves | Non-return valves are
contaminated
- Water pressure too low
- Water flow regulator at the shower head
contaminated
- Flow temperature too low
- Safety stop "warm" on thermostat
cartridge set too low
- Plug connections on solenoid valves
reversed
- Cartridge dirty or defective
- Backflow preventer dirty or defective
- non-return valve clamps
- Filters | Sieves | Backflow preventer dirty
- Cartridge dirty or defective
- Strong pressure fluctuations in the water
supply
defective
POSSIBLE SOLUTION
- Open water supply
- Switch on operating or auxiliary voltage
- Checking the status in the control panel
- Outlet temperature too high
- Check sensors and connectors
- Check connection distributor and dry if
necessary
- Check connectors and dry if necessary
- Replace solenoid valve
- Replacing the piezo button
- Check and establish mains voltage
- Check connectors
- Replacing Piezo Pushbuttons
- Deactivate hygiene flushing
- Replace bus device (CNX)
- Setting the water running time correctly
- Clean or replace solenoid valve
- Clean or replace Filters | Sieves | Non-
return valve
- Check water pressure and increase if
necessary
- Cleaning or replacing water flow regulators
- Check flow temperature and increase if
necessary
- Check and adjust safety stop
- Check solenoid valve 1 & 2 plug
connections
- Clean or replace cartridge
- Check non-return valve
- Replacing the non-return valve
- Clean or replace Filters | Sieves | Non-
return valve
- Clean or replace cartridge
- Investigating and remedying causes
- Clean or replace cartridge