Replacing hoses:
Wear protective clothing and goggles!
Disconnect the suction and pressure sides of the hose from their connections.
Undo the screw of the clear lid and remove the lid.
Remove the suction side hose connection (left) from the holder.
Pull the dosing hose carefully out from under the rollers.
Remove the pressure side of the hose connection (right) from the holder.
Place the new hose with the two connectors into the two holders. Pay attention to
ensure that the connections with the rounded sides are placed facing the device.
Briefly switch on the motor, the hose will be drawn into the correct position under
the hose.
Place the clear lid on the housing and secure using the screw.

5.4 Taking out of operation/wintering the system

If the system is taken out of operation for a longer period of time, for example, over
winter, a number of precautions must be taken. Be particularly careful to ensure
that the entire system is protected from frost and damp.

5.4.1 Dosing system

Rinse the pumps with lukewarm clean water for approximately half an hour. To do
this, put the suction lance into a bucket of tap water and trigger manual dosage.
Make sure that the system is fully disconnected from the mains.
Release the hose set to prevent permanent deformation of the hoses.

5.4.2 Measuring system

The single-rod measuring cells may only be stored damp.
Store the electrodes standing in their sleeves in a frost-free location. The 3-molar
KCL solution in the sleeve protects the electrodes preventing them from drying
out. Alternatively, the electrodes may be stored in clean tap water. Caution: Do
not use distilled water!
Seal both electrode holes of the measuring cell with PG13 plugs
Drain the water from the measuring chamber and the measuring hoses. Close the
taps of the test water extract
-
ion and return.