Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 75
English
2.
Take off the front panel: Undo the screws (D) on the control panel and lift it up. Then undo the screws (E) on
the bottom of the front panel and take it off.
3.
Place a receptacle with a capacity of at least ½ litre under the A/C service unit. The oil from the vacuum
pump flows through the opening (I) in the base of the A/C service unit.
4.
Unscrew the oil filling plug (G).
5.
To drain the oil, unscrew the oil drain plug (J).
6.
Once the oil has been completely drained from the pump housing, screw the oil drain plug (J) back in.
7.
Top up with new vacuum pump oil to the middle of the sight glass (H) and screw the oil filling plug (G) back
in.
8.
Put the front panel and control panel back.
9.
Reconnect the power supply plug.
10. Reset the Vacuum time counter
14.6

Meter readings

The A/C service unit saves various meter readings. To access the total values (consecutively, since the A/C ser-
vice unit was produced) proceed as follows:
1.
Enter the Other selections – Service menu.
2.
Enter the code
3.
Use the cursor keys
4.
To access the meter readings which can be reset, enter the code
the vacuum pump oil
26
(Resetting the counters
.
7783
or
to select the required entry. These meter readings cannot be reset.
on page 25 or
Changing the dryer filter
on page 23).
under Service (see also
7782
on page 23).
Changing