5. Commissioning, operation
5.3 Mounting instructions for instruments with EHEDG and 3-A
Observe the following instructions, especially for EHEDG-certified
and 3-A-compliant instruments.
To maintain the EHEDG certification, one of the EHEDG-recom-
mended process connections must be used. These are marked
with the logo in the data sheet.
To maintain the conformity to the 3-A standard, a 3-A-compliant
process connection must be used. These are marked with the
logo in the data sheet.
Mount the instrument with minimal dead space and able to be
cleaned easily.
The mounting position of the instrument, welding socket and
instrumentation T-piece should be designed to be self-draining.
The mounting position must not form a draining point or cause a
basin to be formed.
With the process connection via an instrumentation T-piece, the
branch L of the T-piece must not be longer than the diameter D of
the T-piece (L ≤ D).
Special instructions for in-line versions
In-line access units (e.g. VARINLINE
T-pieces in horizontal pipes should be installed with a slight pipe
inclination for self-draining.
With in-line access units (e.g. VARINLINE
from the manufacturer and observe their installation instructions.
The welding sockets shall comply with EHEDG documents doc.
9 and doc. 35. With TIG welding, the surface quality must be Ra ≤
0.8 µm. The weld seams must be free from defects on the wetted
and non-wetted contact sides and must be butt welded.
For tank-mounted pressure measuring instruments the tank clean-
ing devices shall be positioned in such a way that the instrument
can be assessed and is perfectly cleaned.
WIKA operating instructions pressure gauge, PG43SA-S, PG43SA-C