Herunterladen Inhalt Inhalt Diese Seite drucken

Connection - led2work LENSLED II Betriebsanleitung

Led-gelenkarm-lupenleuchte
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
As option there are this mounting accessories:
Wall mount bracket for adjustable arm Luminaire
T-slot bracket for adjustable arm Luminaire
Screw-on base, plastics incl. screws for adjustable arm Luminaire
Fastening plate, aluminium
Universal table clamp (spare part)

5 | Connection

Suitable connection material, cables and accessories can be found in the accessory range of LED2WORK.
Operate the luminare with the supplied power supply unit (PSU) only! No direct connection to 230V AC or other
electric power supplies!
PIN assignment of the M12 connector is as follows:
PIN assignment
PIN 1
= 24V DC
PIN 2
= not used
PIN 3
= GND
PIN 4
= 24V DC
PIN 5
= not used
10 | BA LENSLED II . BA 03/2022
When mounting the luminaire, make sure that the luminaire is fastened securely and
stably. If the luminaire falls down, its weight poses a risk of injury!
Schematic drawing of M12 plug
Possible variants of the M12 connector
PIN 3 = 0V DC. 24V DC for supply can be connected to PIN1 or PIN 4. It is not necessary to
assign both PINs (PIN 1 and PIN 4) at once!
To turn on the luminaire, activate the push button on top the head of the luminaire. Hold
on the push button for setting of the light intensity. A repeated pushing of the button turns
the light off.
Product no.
215100-01
215200-01
215400-01
215400-02
215600-01