4. Technical data

Mains voltage: ........................ 230-240 V ~ 50 Hz
Power input: .............................................. 650 W
Idling speed 1: ..................................0-3000 min
Drilling capacity ......................... Concrete 13 mm
......................................................... Steel 10 mm
........................................................ Wood 25 mm
Protection class: ............................................ II/
Weight: .......................................................2.1 kg
Danger!
Sound and vibration
Sound and vibration values were measured in
accordance with EN 60745.
L
sound pressure level ..................... 93,3 dB(A)
pA
K
uncertainty ............................................. 3 dB
pA
L
sound power level ..................... 104,3 dB(A)
WA
K
uncertainty ............................................. 3 dB
WA
Wear ear-muff s.
The impact of noise can cause damage to hea-
ring.
Total vibration values (vector sum of three direc-
tions) determined in accordance with EN 60745.
Hammer drilling in concrete (handle)
Vibration emission value a
K uncertainty = 1.5 m/s
Hammer drilling in concrete
(additional handle)
Vibration emission value a
K uncertainty = 1.5 m/s
Drilling in metal (handle)
Vibration emission value a
K uncertainty = 1.5 m/s
Drilling in metal (additional handle)
Vibration emission value a
K uncertainty = 1.5 m/s
The specifi ed vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equip-
ment is used and may exceed the specifi ed value
in exceptional circumstances.
Anleitung_RT_ID_65_1_SPK9.indb 17
Anleitung_RT_ID_65_1_SPK9.indb 17
-1
= 16.306 m/s
2
h, ID
2
= 12.345 m/s
2
h, ID
2
= 5.848 m/s
2
h, D
2
= 1.818 m/s
2
h, I
2
- 17 -
GB
The specifi ed vibration value can be used to
compare the equipment with other electric power
tools.
The specifi ed vibration value can be used for initi-
al assessment of a harmful eff ect.
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect wor-
king order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever ne-
cessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
Warning! The electric power tool generates an
electromagnetic fi eld during operation. Under cer-
tain circumstances this fi eld may actively or passi-
vely impede medical implants. To reduce the risk
of serious or fatal injuries, we recommend per-
sons with medical implants to consult their doctor
and the manufacturer of the medical implant prior
to using the equipment.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.

5. Before starting the equipment

Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Warning!
Always pull the power plug before making
adjustments to the equipment.