7.4 External cover

1. Unpack the external shutter with external cli-
mate sensor and remove outer piece. To re-
lease the outer piece's locking hook, unlock
(→ arrow) using a screwdriver.
Do not remove the sensor connection cable
from the external climate sensor. It is con-
nected to the fan, through the duct, when
the housing is mounted.
2. Fit supplied sealing strip centred in socket.

7.5 Fan

1. Unpack unit and take off cover.
2. To release the cover's locking hook, unlock
using a screwdriver.
3. Remove internal climate sensor.

8 Installation and commissioning

5 Internal climate sensor
6 Electronics cover
4. Remove the electronics cover. Unlock locking
hook (→ arrow) with screwdriver.
5. Fit supplied sealing strip centred in socket.
6. Fit supplied foam strip centred in socket.
The foam strip must be fitted on the unit so
that the units do not draw in any unwanted air
from outside.
8 Installation and commissioning

8.1 Installation

When installing the FE 100/1 window in-
stallation kit or the ECA-DR spacing frame, →
associated installation instructions.