3.6. Electric heater insulation resistance

When performing the final inspection of the electri-
cal installations, a "leakage" may be detected when
measuring the heater's insulation resistance. The
reason for this is that the insulating material of the
heating resistors has absorbed moisture from the
air (storage transport). After operating the heater
for a few times, the moisture will be removed from
the resistors.
Do not connect the power feed for the heater
through the RCD (residual current device)!
Figure 14.
Electrical connections of JM heater in Japan
Abbildung 14. Elektroanschlüsse des JM Saunaofens in Japan
18
DE
3.6. Isolationswiderstand des
Elektrosaunaofens
Bei der Endkontrolle der Elektroinstallationen kann
bei der Messung des Isolationswiderstandes ein
"Leck" auftreten, was darauf zurückzuführen ist,
daß Feuchtigkeit aus der Luft in das Isolationsmateri-
al der Heizwiderstände eingetreten ist (bei Lagerung
und Transport). Die Feuchtigkeit entweicht aus den
Widerständen nach zwei Erwärmungen.
nicht über den Fehlerstromschalter ein!
Figure 15.
Electrical connections of JM heater in Norway
Abbildung 15. Elektroanschlüsse des JM Saunaofens in Norwegen
Schalten Sie den Netzstrom des Elektrosaunaofens