3-5. Service Setup
30. Pump maximum speed
Normally setting is not necessary.
Please adjust when need to reduce the pump sound etc.
Besides that, it has Air Purge function.
31. Pump down
Operate pump down operation
32. Dry concrete
Operate concrete curing operation.
Select Edit, set temp for every stage (1~99 1 is for 1 day).
Setting range is 25~55°C
When it is turned ON, dry concrete starts.
When it is 2 zone, it dries both zones.
33. Service contact
Able to set name & tel no. of contact
person when there is breakdown
etc. or client has trouble. (2 items)
Initial setting: Depend on model
Service setup
Pump down:
ON
Confi rm
Service setup
Service contact:
Contact 1
Contact 2
Select
Confi rm
Service setup
Flow rate
88:8 L/min
Select
12:00am,Mon
Service setup
Pump down:
45°C
40°C
40°C
35°C
30°C
1
2
3
4
12:00am,Mon
Contact-1: Bryan Adams
ABC/ abc
A B C D E F G H I J K L M N O P Q R
S T U V W X Y Z
j k l m n o p q r s t u v w x y z
Select
12:00am,Mon
Max. Duty
Operation
Air Purge
0xCE
17:26, Wed
Pump down operation
in progress!
ON
OFF
Confi rm
35°C
5
6
Stage
0-9/ Other
a b c d e f g h i
Enter
29