Herunterladen Inhalt Inhalt Diese Seite drucken

Panasonic WH-ADC1216H6E5 Installationshandbuch Seite 16

Vorschau ausblenden Andere Handbücher für WH-ADC1216H6E5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 245
Optional cables:
2-way valve cable
Extra pump cable
Boiler contact cable
Optional cables:
Optional cables:
External control cable
Outdoor air sensor cable
Remote controller cable
Room sensor zone 1 cable
Room sensor zone 2 cable
Buffer tank sensor cable
Pool sensor cable
Water sensor zone 1 cable
Water sensor zone 2 cable
Demand signal cable
Solar sensor cable
SG signal cable
Heat/Cool switch cable
External Compressor switch cable
Terminal screw on PCB
M3
M4
Connecting Cables Length
When connecting cables between Tank Unit and external devices,
the length of the said cables must not exceed the maximum length
as shown in the table.
External device
Two-way valve
Mixing valve
Room thermostat
Extra pump
Solar pump
Pool pump
Pump
Boiler contact
External control
Room sensor
Outdoor air sensor
Buffer tank sensor
Pool water sensor
Solar sensor
Water sensor
Demand signal
SG signal
Heat/Cool switch
External compressor switch
16
Power Supply 1 cord
Power Supply 2 cord
Indoor Unit/Outdoor
Unit Connecting cable
Pump zone 1 cable
Pump zone 2 cable
Solar pump cable
from Optional
Pool pump cable
PCB
Room thermostat zone 1 cable
Room thermostat zone 2 cable
Mixing valve zone 1 cable
Mixing valve zone 2 cable
from Optional PCB
Maximum tightening torque cN•m {kgf•cm}
50 {5.1}
120 {12.24}
Maximum cables length (m)
50
50
50
50
50
50
50
50
50
30
30
30
30
30
30
50
50
50
50
Connection of the main PCB
C O N C O N
2-way
3-way
valve
valve
 
Signal inputs
L N =AC230V, Heat, Cool=Thermostat heat, Cool
Optional Thermostat
terminal
It does not function when using the Optional PCB
Dry contact Open=not operate, Short=operate
(System setup necessary)
External control
Able to turn ON/OFF the operation by external
switch
Connected (Please use 2 cores wire for relocation
Remote controller
and extension. Total cable length shall be 50m
or less.)
 
Outputs
AC230V N=Neutral Open, Close=direction (For
3-way valve
circuit switching when connected to DHW tank)
AC230V N=Neutral Open, Close (Prevent water
2-way valve
circuit pass through during cooling mode)
AC230V (Used when Tank Unit pump capacity is
Extra pump
insuffi cient)
Boiler contact
Dry contact (System setup necessary)
 
Thermistor inputs
Zone 1 room
PAW-A2W-TSRT
sensor
the Optional PCB
Outdoor air
AW-A2W-TSOD (Total cable length shall be 30m
sensor
or less)
Connection of Optional PCB (CZ-NS4P)
Optional
Optional
Thermostat 2
Thermostat 1
L
N Cool Heat L
Pool
Pump
Solar
Pump
Error
signal
Zone 1
Pump
Zone 2
Pump
Zone 2
Zone 1
Buffer
room
room
Tank
sensor
sensor
sensor
Zone 1 room sensor
Outdoor air sensor
Tank sensor
External control
Remote controller
Boiler contact
Extra pump
H C N L
Optional
Thermostat 1
It does not work when using
Mixing
Mixing
valve 1
valve 2
N Cool Heat
N
O
C
N
O
C
Pool
Zone 2
Zone 1
Demand
Solar
sensor
water
water
water
signal
sensor
sensor
sensor
Ext.
comp.
SW
Heat/
Cool
SW
Vcc
SG
Bit1
signal
Bit2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis