Herunterladen Inhalt Inhalt Diese Seite drucken

Product Description And Specifications - Bosch GCL 25 Professional Originalbetriebsanleitung

Laser
Vorschau ausblenden Andere Handbücher für GCL 25 Professional:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6
OBJ_BUCH-1546-003.book Page 12 Wednesday, May 14, 2014 4:32 PM
12 | English
Keep the measuring tool and the laser
target plate 13 away from cardiac pace-
makers. The magnets of the measuring tool
and laser target plate generate a field that can
impair the function of cardiac pacemakers.
 Keep the measuring tool and the laser target plate 13
away from magnetic data medium and magnetically-
sensitive equipment. The effect of the magnets of the
measuring tool and laser target plate can lead to irrevers-
ible data loss.
Product Description and
Specifications
Please unfold the fold-out page with the representation of the
measuring tool and leave it unfolded while reading the operat-
ing instructions.
Intended Use
The measuring tool is intended for determining and checking
horizontal and vertical lines as well as plumb points.
Product Features
The numbering of the product features shown refers to the
illustration of the measuring tool on the graphic page.
1 Exit opening for laser beam
2 Operating mode button
3 Battery low indicator
4 On/Off switch
5 Magnets
6 Tripod mount 5/8"
7 Tripod mount 1/4"
8 Latch of battery lid
9 Battery lid
10 Laser warning label
11 Serial number
12 Laser viewing glasses*
13 Laser target plate
14 Measuring plate with stand*
15 Universal holder*
16 Tripod*
17 Case
* The accessories illustrated or described are not included as
standard delivery.
1 609 92A 0KZ | (14.5.14)
Technical Data
Point and line laser
Article number
1)
Working range
– Laser lines
– Horizontal point beams
– Point beam, upward
– Point beam, downward
Levelling accuracy
– Laser lines and horizontal
point beams
– Vertical point beams
Self-levelling range, typically
Levelling duration, typically
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
C
6
Tripod mount
Batteries
Battery life for the operating
modes
– Cross and point-line operation
– 5-point operation
– Line operation
Weight according to
EPTA-Procedure 01/2003
Dimensions
(length x width x height)
Degree of protection
1) The working range can be decreased by unfavourable environmental
conditions (e.g. direct sun irradiation).
The measuring tool can be clearly identified with the serial number 11
on the type plate.
Assembly
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for the
measuring tool.
To open the battery lid 9, slide the latch 8 in the direction of
the arrow and fold the battery lid up. Insert the batteries.
When inserting, pay attention to the correct polarity accord-
ing to the representation on the inside of the battery lid.
GCL 25
3 601 K66 B00
10 m
30 m
10 m
5 m
±0.3 mm/m
±0.5 mm/m
±4°
<4 s
–10 °C ... +50 °C
–20 °C ... +70 °C
90 %
2
635 nm, <1 mW
1
1/4", 5/8"
4 x 1.5 V LR06 (AA)
12 h
24 h
30 h
0.6 kg
155 x 56 x 118 mm
IP 54 (dust and splash
water protected)