LCD Screen operation - Section F
G
Settings
In the Settings mode you will be able to access the following:
Set Date / Time

Set Temperature

Zip HydroTaps are designed to operate within 1 to 2 °C of set point
for boiling water and between 5 to 10 °C for chilled drinking water.
All boiling water units are self calibrating to 98 °C, which is the
recommended setting. Adjustments to the 98 °C setting are not
recommended however, under certain circumstances adjustments
may be made between 68 to 100 °C. It should be noted that a energy
saving in standby power can be achieved when the 98 °C setting is
selected over the 100 °C setting. Furthermore, the 100 °C setting is
not recommended as the delivery rate of water may be aff ected.
1. Press the [MENU] button for
main menu.
2. Press the [Settings] button.
3. Then enter your 4 digit pass-
word if you have set one.
1. Press the [MENU] button for
main menu.
2. Press the [Setting] button.
3. Press the [Date/Time] button.
4. Choose 12 hour mode or 24
hour mode by pressing the
square button. The selected
mode will be displayed in dark
grey colour with a tick box on
the right.
5. Press [NEXT] button to set
time.
1. Press the [MENU] button for
main menu.
2. Press the [Temperature]
button.
3. To adjust the temperature, use
the up and down arrows.
33