Installation detail
•
PLEASE NOTE: The edge must be absolutely flat when installed. If the cover plate is subjected to
mechanical tension, this can lead to cracks or even breakage of the plate when heated.
•
PLEASE NOTE: It is recommended not to use wood as a support for the induction cover plate, as wood
expands with moisture and heat and the flat support of the plate described above is no longer given.
Ideally, the cut-out in the buffet top plate should be selected so that the induction top plate lies absolutely
flat/level on it, as shown in the following sectional diagram.
Size Buffet
Covermaterial
A
>30 mm
32
Size Induction
Covermaterial
Pedstal
B
C
20 mm
>8 mm
15 mm
>8 mm
12 mm
>8 mm
Graph and table : Ideal, recommended construction
Distance to
IW130+
Air Gap
D
E
>15 mm
-
>15 mm
5 mm
>15 mm
8 mm
Silicon
Gap
F
3 mm
3 mm
3 mm