Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Kärcher HD 10/23-4 SX Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für HD 10/23-4 SX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Before each use
 Check connection cable for damages
(risk of electrical shock); get the dam-
aged connection cable replaced imme-
diately by an authorised customer
service person/ electrician.
 Check the high pressure hose for damages
(risk of bursting).
Please arrange for the immediate ex-
change of a damaged high-pressure hose.
 Check appliance (pump) for leaks.
3 drops per minute are permitted and
can come out from the lower side of the
appliance. Call Customer Service if
there is heavy leakage.
 Check oil level Please contact Custom-
er Service immediately if the oil is milky
(water in oil).
 Clean the fine filter.
Unpressurize the appliance.
Unscrew the fastening screws of the
device hood; remove the device hood.
Unscrew lid with filter.
Clean the filter with clean water or com-
pressed air.
Reinstall in reverse sequence.
 Clean filter at the detergent suck hose.
monthly or after 500 operating
 Oil change.
Oil change
Note
See "Technical Details" for details of oil
quantity and type.
 Unscrew the fastening screws of the
device hood; remove the device hood.
 Turn out the oil drain screw at the front
on the motor casing.
 Drain the oil in a collection basin.
 Turn out the oil drain screw.
 Fill in new oil slowly; air bubbles should
go out.
 Attach the lid of the oil container.
 Fasten the device hood.
20
Weekly
hours
 Empty and clean the detergent tank.
Pull out the locking cap for the deter-
gent tank along with the suction hose.
Lay the device on the reverse.
Empty and clean the detergent tank.

Troubleshooting

Danger
Risk of injury by inadvertent startup of ap-
pliance and electrical shock.
First pull out the plug from the mains before
carrying out any tasks on the machine.
Get the electrical components checked and
repaired only by authorised customer serv-
ice persons.
Contact an authorised customer service
person in case of problems not mentioned
in this chapter or if you are in doubt or when
you have been explicitly asked to do so.
Appliance is not running
 Check connection cable for damages.
 Call Customer Service in case of elec-
trical defects.
Pressure does not build up in the
 Install the high pressure nozzle.
 Clean/ replace nozzle.
 Clean the fine filter; replace it, if neces-
sary.
 Deaerate the appliance (see "Start-up")
 Check water supply level (refer to tech-
nical data).
 Check all inlet pipes to the pump.
 Contact Customer Service if needed.
3 drops per minute are permitted and can
come out from the lower side of the appli-
ance. Call Customer Service if there is
heavy leakage.
 With stronger leak, have device
checked by customer service.
– 6
EN
If required
appliance
Pump leaky

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hd 10/23-4 s

Inhaltsverzeichnis