• The machine must not be used in rooms where
there is a risk of explosion under any circumstanc-
es.
• The working temperature must be between +5 and
50°C. Do not cover or make changes to the lance
or spray nozzles.
• The high-pressure cleaner is designed for opera-
tion with cold or moderately warm water (max. up
to 50°C); higher temperatures will cause damage
to the pump.
• The incoming water must not be dirty, sandy or
contaminated with chemical products that can im-
pair the function and decrease the durability of the
machine.
Assembly
Device assembly (Fig. 1, 2, 3, 4)
Push the handle with hose reel (1) onto the fastening
points at the top of the device and secure using the
two screws provided (12). (Length 20 mm)
Attach the lance holder (7) and the cable holder (4)
onto the side of both fastening points on the device.
Hose reel (Fig. 1)
The hose reel facilitates the space-saving storage of
the high pressure hose (3).
With the aid of the crank handle (2), it is possible to
wind the high pressure hose (3) onto the hose reel.
Attention! In order to use the high pressure clean-
er it is necessary to fully unwind the high pressure
hose.
Water supply connection (Fig. 1, 6)
Screw the connection for the water supply (10) onto
the device. Remove the protective cover first. The
connection for the water supply (10) features a con-
nection for standard hose coupling systems. Attach
the hose coupling of the supply hose (min. Ø 1/2"/
approx. 13 mm) onto the connection for the water
supply (10).
Always use an enhanced water hose with an in-
dustry-standard coupling for the water supply. The
length should be at least 6.0 m. (not included in the
scope of delivery)
A backflow prevention device must be installed be-
tween the drinking water and the high-pressure
cleaner! Ask your plumbing expert about this.
Suction from open tanks/containers and natural
bodies of water
Use a special self-suction accessory (not included
with delivery / available from dealer)
With this accessory, the high-pressure cleaner can
take in water 0.5 m above the water level. This can
last about 25 to 50 seconds.
Immerse the accessory's hose completely under wa-
ter to drive the air out of the hose.
22 | GB
Connect the accessory's hose to the high-pressure
cleaner, and make sure that the suction strainer re-
mains under water.
Let the high-pressure cleaner run with the spray gun
removed until the water flows evenly out of the high-
pressure hose. If no water comes out after 25 to 50
seconds, switch off and check all connections.
Once the water is flowing, turn off the high-pressure
cleaner and connect the spray gun and spray lance
to start work.
High-pressure hose connection (Fig. 5/7)
Connect the high-pressure hose (3) to the connec-
tion for the high-pressure hose (6). Remove the pro-
tective cover first.
Insert the other end of the high-pressure hose (3)
into the pistol connection (16).
To remove the high-pressure hose (3), press the but-
ton Taste (A) and pull it out.
Connecting the attachments (Fig. 8)
To fit the extension piece (15), push it into the pistol
(16) and turn until it locks.
To mount the attachments (13) and (14), insert these
into the extension piece (15) and turn them until they
lock.
To remove the attachments (13) and (14), press the
button Taste (B) and pull it out.

9. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions. The
customer's mains connection as well as the ex-
tension cable used must also comply with these
regulations.
Important information
In the event of overloading, the motor will switch itself
off. After a cool-down period (time varies) the motor
can be switched back on again.
• The product meets the requirements of EN 61000-
3-11 and is subject to special connection condi-
tions. This means that use of the product at any
freely selectable connection point is not allowed.
• Given unfavorable conditions in the power supply
the product can cause the voltage to fluctuate tem-
porarily.
• The product is intended solely for use at connec-
tion points that
a)do not exceed a maximum permitted supply im-
pedance "Z" (Zmax. = 0.384 Ω), or
b) have a continuous current-carrying capacity of
the mains of at least 100 A per phase.
• As the user, you are required to ensure, in consulta-
www.scheppach.com