Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11

TROUBLESHOOTING

Switch off the device before any procedure and unplug the power cable from the socket.
PROBLEM
The device does not work
The device does not
nebulize or
nebulizes insufficiently.
The apparatus is noisier
than usual
If after verifying the above mentioned conditions the device should not operate properly, contact your trusted retailer or
the nearest authorized FLAEM service center.
SYMBOLS
CE Medical Marking ref. Dir. 93/42 EEC and
subsequent amendments
Class II device
Important: check the operating instructions
"OFF" for part of equipment
"ON" for part of equipment
Complies with: European standard EN 10993-
1 "Biological Evaluation of Medical Devices"
and European Directive 93/42/EEC "Medical
Devices". Phthalates free. In conformity with
Reg. (EC) no. 1907/2006
Minimum and maximum room temperature
Minimum and maximum atmospheric pressure
CAUSE
The power cable has not been cor-
rectly inserted into the power socket
The medication has not been inserted
in the nebulizer
The nebulizer has not been properly
fitted.
The nebulizer nozzle is clogged
The air pipe is not correctly connected
to the device
The air pipe is bent, damaged or
twisted
The air filter is dirty
The Filter is not correctly
inserted in its housing
SOLUTION
Correctly insert the power cable in sockets.
Pour the right amount of medication in the
nebulizer
Disassemble the nebulizer and
reassemble it correctly as shown in the connection
diagram on the cover.
Disassemble the nebulizer, remove the nozzle and
perform cleaning operations.
Failure to remove medication deposits from the
nebulizer affects its efficiency and operation.
Strictly comply with the instructions contained
in the "CLEANING, SANITISATION DISINFECTION"
chapter
Ensure the device's accessories
are properly connected to the air intake (see
connection diagram on the cover).
Unwind the pipe and ensure it is
not crushed or punctured. If necessary replace it.
Replace the filter
Fully and properly insert the Filter in its housing
Serial number of device
Manufacturer
Type BF applied part
Alternating current
Enclosure protection rating: IP21.
(Protected against solid bodies over 12 mm.
IP21
Protected against access with a finger; Protected
against vertically falling water drops).
Minimum and maximum air moisture
7

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

4.0y301p00

Inhaltsverzeichnis