Herunterladen Inhalt Inhalt Diese Seite drucken

Addressing Via Dmx-Rdm - Oase Jumping Jet Rainbow Flash II DMX/02 Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

- EN -
7.4

Addressing via DMX-RDM

DMX-RDM
This unit supports the DMX protocol extension RDM. RDM (Remote Device Management) is a new, open
and bi-directional protocol standard for DMX-512 controlled units. The protocol allows to receive status
information about a unit or to change configurations on a unit. Prerequisite for this function being an RDM
compatible controller. E.g. Oase WECS 1024.
RDM (Remote Device Management) is a new, open and bi-directional protocol standard for DMX-
controlled devices. The permanently transmitted DMX data flow briefly pauses (several milliseconds), and
an RDM data package (message) is sent directly to a subscriber. The subscriber evaluates the information
in the data package and sends an answer (semi-duplex) on the same line. Targeted polling to a subscriber
via its UID (Unique ID) prevents several subscribers from answering simultaneously.
RDM parameter overview:
General parameters
COMMS_STATUS
STATUS_MESSAGES
STATUS_ID_DESCRIPTION
SUPPORTED_PARAMETERS
PARAMETER_DESCRIPTION
DEVICE_INFO
PRODUCT_DETAIL_ID_LIST
DEVICE_MODEL_DESCRIPTION
MANUFACTURER_LABEL
DEVICE_LABEL
SOFTWARE_VERSION_LABEL
DMX_PERSONALITY
DMX_START_ADDRESS
SENSOR_DEFINITION
SENSOR_VALUE
RECORD_SENSORS
IDENTIFY_DEVICE
RESET_DEVICE
28
All manuals and user guides at all-guides.com
GET
SET
Description
CMD
CMD
*
*
Shows general status information of the bus interface
*
Used to manage status messages
*
*
RDM parameter overview
*
Description of all parameters
*
Brief overview of the most important features
*
Additional feature
*
Type designation
*
Manufacturer name
*
*
Labelling field
*
Version number of the firmware
*
*
Operating behaviour (currently the setting cannot be changed)
*
*
Reading and setting the DMX start address
*
Sensor information
*
Sensor value
Sensor 1 = „Temp", current operating temperature
Sensor 2 = „TempErrWord", temperature error counter
Sensor 3 = „VoltageSupply", input voltage
*
Buffering the sensor value
*
*
0 = Normal operation,
1 = Shutter, fontaine on/out
*
Executes a reset.
1 = Warm start / 255 = Cold start