- All persons involved in work on the refrigerant circuit must have a valid certificate from an
industry accredited certification body that ensures competence in handling refrigerants
according to a specific assessment recognized by industry associations.
- Take precautions so that the device cannot be damaged while in storage.
- Store the device in a well ventilated location where the room size corresponds to the
room area specified for operation.
Risk of injury through insufficient qualification!
Insufficient experience or skills for handling the required tools and insufficient knowledge of
regional or normative regulations for the required work can lead to severe injuries or material
damage.
- Assign all work whose risks you cannot estimate due to insufficient personal experience
to a qualified expert.
Faulty electric installation or excess mains voltage can cause an electric shock.
- Have the installation, initial start-up and maintenance of the heat pump carried out by
authorized specialists only.
- Do not start work on the heat pump before all safety instructions have been complied
with.
- Work on the heat pump may only be carried out when it is de-energized.
- Only connect the heat pump if the mains voltage of the socket matches that on the type
plate.
- Only connect the heat pump to an easily accessible socket so that you can quickly
disconnect the heat pump in the event of a fault.
- Do not operate the heat pump if there is visible damage or if the power cable or power
plug is defective.
- If the power cable of the heat pump is damaged, it must be replaced by the manufacturer,
its customer service or a qualified person to prevent hazards.
- Do not open the housing. Let specialists perform any repairs. All liability and warranty
claims will be void in the case of arbitrary repairs, improper connection or wrong
operation.
- Only parts that match the original device data may be used for repairs. This heat pump
contains electrical and mechanical parts that are essential for protection against sources
of danger.
- Do not operate the heat pump with an external timer or a separate remote control
system.
- Do not immerse the heat pump, power cable or power plug in water or other liquids.
- Never touch the power plug with wet hands.
- Never pull the power cable to disconnect the power plug from the socket. Always
disconnect by holding the power plug.
- Never use the power cable as a carrier handle.
- Keep the heat pump, power plug and power cable away from open fires and hot
surfaces.
- Make sure that the power cable does not present a trip hazard.
- Do not bend the power cable or position it over sharp edges.
- Make sure that children do not put objects into the heat pump.
- Keep the openings free from foreign objects.
- When the heat pump is not in use, is being cleaned, or if a fault occurs, always switch off
the heat pump and disconnect its power plug from the socket.
- Make sure that the actual operating voltage does not deviate from the nominal value by
more than 10% (see "Technical Data").