Herunterladen Inhalt Inhalt Diese Seite drucken

Kernau KGH 6434 T CI B Bedienungsanleitung Seite 38

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9) TAPS
"Reduced rate" adjustment
- Switch on the burner and turn the relative knob to
the "Reduced rate" position (small flame fig. 1).
- Remove knob "M" (fig. 12 and 12/A) of the tap,
which is simply pressed on to its rod. The by-pass
for minimal rate regulation can be: beside the tap
(fig. 12) or inside the shaft. In any case, to access
to regulation, it can be done trought the insertion
of a small screwdriver ''D'' beside the tap (fig. 12)
or in the hole ''C'' inside the shaft of the tap
(fig 12/A). Turn the throttle screw to the right or left
until the burner flame has been adequately
regulated to the "Reduced rate" position.
FIG. 12
REGULATION
TAPS LUBRIFICATION
Should a tap being blocked, do not
force and ask for Technical
Assistance.
The flame should not be too low: the lowest small
flame should be continuous and steady. Re-
assemble the several components.
It is understood that only burners operating
with G20 gas should be subjected to the above
mentioned adjustments. The screw must be
fully locked when the burners operate with G30
or G31 (turn clockwise).
FIG. 12/A
14

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Kgh 7534 t ci b

Inhaltsverzeichnis