5
Dispensing
5.3
Adjusting the Dispensed Quantity
5.3.1
Time Controlled Mode
This mode of operation is used for spot shaped wetting or drop dispensing.
• With buttons
time to 0.50 s. The indication of the
dispensing time in the digital display begins
blinking.
• With the pressure regulator set the
dispensing pressure to 0.5 bar
(approx. 7 PSI).
If the dispensed quantity is too small:
• Increase the dispensing pressure. After this
check the dispensed quantity.
Repeat this sequence until the desired
dispensed quantity is roughly achieved.
When the desired dispensed quantity is roughly achieved:
• Set the exact dispensed quantity by changing the dispensing time
with button
• Press the footswitch to check the dispensed quantity.
Storing of the dispensed quantity setting for subsequent dispensing:
• Press button
blinking.
If the desired dispensed quantity is not achieved:
• With a larger (or smaller) dispensing needle, repeat the steps of this section.
5.3.2
Continuous Mode
This mode of operation is used for the application of beads.
• With the pressure regulator 12 set the dispensing pressure to 0.5 bar (approx. 7 PSI).
• Press the buttons
simultaneously. The lighting of the LED
"CONT." indicates Continuous mode. The
display of the dispensing time in the digital
display is set to con.
• Press the button
check if the product is ejected quickly
enough from the dispensing needle.
When the dispensed quantity is achieved too slowly:
• Increase the dispensing pressure or repeat this sequence with a larger dispensing
needle.
– Switching back to time controlled mode without storage of the dispensing time by
renewed pressing of button
dispensing time is blinking.
– Switching back to time controlled mode with storage of the dispensing time by
pressing button
or
set the dispensing
or
.
. The indication of the dispensing time in the digital display stops
and
(or the foot switch) to
or
. The LED extinguishes. The indicated dispensing time is stored.
. The LED extinguishes. In the digital display, the
13