3
Technical Data
3.1
Energy Requirements
3.1.1
Electrics
Internal control voltage
3.1.2
Pneumatics
If the required quality is
LOCTITE
Regulation range of the
3.2
Connections and Dimensions
3.3
Other Data
Operation Temperature
Continuous noise level
3.4
Safety Device
10
Power supply
Power consumption
Power protection
Pneumatic supply
Quality
not achieved, install a
filter regulator.
®
pressure regulator
Pressure indication
Power connection
Dimensions
Pneumatic supply
Weight
Storage Temperature
Over-pressure safety
(rupture disc)
Power supply 90 – 260 V AC; 47 – 63 Hz
Approx. 25 W
Glass tube, fine wire fuse, 2 A semi time-lag
24 V DC
Min. 5 bar (70 PSI), max. 10 bar (145 PSI)
Filtered 10 µm, oil-free, non-condensing
Order Code no. see Section 9.1
97009
RC18
0-4 bar
0-0.7 bar
(0-58 PSI)
(0-10 PSI)
0-4 bar
0-1 bar
(0-58 PSI)
(0-14 PSI)
Cold appliance coupling IEC 320 acc. to VDE 0625
W x H x D: 350 x 335 x 230 mm (13.8 x 13.2 x 9.1 inch)
Internal Dia. 4 mm; external Dia. 6 mm +0.05, -0.10
External Dia. ¼ in. is not suitable!
7.5 kg
+10 °C to +40 °C (+50 °F to +104 °F)
-10 °C to +60 °C (+14 °F to +140 °F)
< 65 dB(A)
min. 9 bar (130 PSI); max. 12.5 bar (174 PSI)
Tightening torque of the rupture disc max. 20 Nm