FEATURES OF THE AMPLIFIER AND CONTROL SECTIONS

The class D digital amplifier is the heart of the VIO-X206
modules.
It allows delivering up to 900 W RMS, silently and efficiently.
System is controlled by a powerful DSP allowing an immediate
and quick configuration of the line-array in any context of use.
Thanks to the possibility of a networking with RDNet, the
parameters on the panel can be remotely controlled through the
"AURORA NET" software (refer to
REMOTE CONTROL
paragraph) 3
The DIGIPRO G3 panel is made up of:
Input, Output and Control Section
Power Supply Unit Section
!
WARNING
Never attempt to disassemble the amplifier in
any way.
In the event of a malfunction, remove power
supply immediately by disconnecting the
unit from the power mains and contact an
authorised repair centre.
Preferably use cables with original, high quality
Neutrik® connectors. Periodically check their
integrity.
The loudspeaker is provided with a fuse installed
at the factory for operation in the 220-240 V
voltage range. If you need to operate in the 100-
120 V range:
1.
2.
3.
WARNING
Never remove the front grille protecting the product.
To prevent the danger of electric shock, in case of accidental damage or replacement of the pro-
tection grille (to be carried out at the service), disconnect power supply immediately.
Never connect mains power supply when the grille is removed.
VIO-X206
DSP PRESET PARAMETERS AND
Disconnect all connections, including
the power supply connection.
Wait 5 minutes.
Replace the fuse with the fuse rated for
the 100-120 V range, which is included
in the package.
!
RDNet
Data Out
Data In
P P U U S S H H
P P U U S S H H
USB
Data
Service
Remote
Preset
Link Active
Active
Balanced
Attenuation
Status
Audio
Input
Link
P P U U S S H H
P P U U S S H H
output
Limiter
-6dB
-9dB
-3dB
Signal
-12dB
-2dB
Status
-1dB
-15dB
ON
0dB
User/Service
mute
HORN
HF correction
model
60-90
WAVE
HF1
HF2
GUIDE
6
CAUTION
ATTENTION
This device complies with part 15 of the
RISK OF ELECTRICAL SHOCK
RISQUE DE CHOCH ELECTRIQUE
FCC Rules. Operation is subject to the
DO NOT OPEN
NE PAS OUVRIR
following two conditions: (1) This device
may not cause harmful interference, and
(2) this device must accept any interference
AUTO-RANGE
MAINS LINK
received, including interference that may
MAINS INPUT
cause undesired operation.
MAINS FUSE
AEB INDUSTRIALE S.R.L.
Via Brodolini, 8
Località Crespellano
40053 VALSAMOGGIA (BO)
ITALY
220-240V~ 14,4Amax
220-240V~ (T3,15A L 250V~)
220-240V~ 50-60Hz 1,6A
100-120V~ 50-60Hz 2,7A
3310Wmax
100-120V~ (T6,3A L 250V~)
100-120V~ 17,3Amax
(REPLACE FUSE WITH SAME RATINGS)
1900Wmax
(REMPLACER LE FUSIBLE AVEC LE MÊME TYPE)