Herunterladen Inhalt Inhalt Diese Seite drucken

Broadcast - Honeywell PEHA Compact 952 JRM Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für PEHA Compact 952 JRM:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

All manuals and user guides at all-guides.com
OPERATIOn

BROADCAST

D e v i c e m e n u
M o d e
Enter
Mo d e :
OFF
12 Broadcast
Enter
Prog
Selection:
Setting:
Finish:
Prog
Prog
Factory setting
Mode
Sensors
Mode: Off
Off, Master, Slave
external (Ext.): External Sensor data
Internal (Int.): Internal Sensors
Note: A system with more than one compact module can be controlled with the one common set of sensors. The modules must be interlinked via
the compact bus (see page 24). The module with the connected sensors must be configured as the first module in the bus and as the master. All
of the following modules are configured as slaves. The sensor data are transmitted via the compact bus every two minutes and every time the
sensor value changes. A mode change reboots the module!
GB-18
M o d e
Mo d e :
Slave
A uto m a ti c :
E x t
.
T w i l i g h t:
Ext.
S un 1:
Ext.
S un 2:
Ext.
S un 3:
Ext.
W i nd :
Ext.
Setting:
Selection:
Enter
External sensor data (compact bus)
• Automatic
• Wind / Rain
• Twilight
• Sun 1
• Sun 2
• Sun 3
Internal Sensors
Module inputs I30-I35