Herunterladen Inhalt Inhalt Diese Seite drucken

Mode Of Operation; Intended Use; Foreseeable Misuse; Safety Devices - HEYLO BT 60 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Dehumidifier BT 60
5
4
Fig. 25: Rear view
1 Control panel
3 Power cord
5 Air outlet
The scope of delivery includes:
– Dehumidifier
– Filter mat
– Operating manual
The following accessories are available:
– Hygrostat
– Simplify remote monitoring system

Mode of operation

Fig. 26: Air flow through device
Air flow through the device (see also Cooling circuit
[
40]):
– The fan takes in humid air, which enters the de-
vice through the air intake opening and a filter.
– At the condenser, the air is cooled and the re-
sulting water droplets are collected in the water
tank.
– Subsequently, the air is heated to approx. +5 °C,
by the evaporator and other powered compo-
nents of the device.
28 / 42
1
2
3
2 Jack socket
4 Socket for remote
monitoring data ca-
ble (Simplify)
As air repeatedly passes through the device, the
humidity in the room is gradually reduced. This en-
sures fast and safe dehumidification.
Unless the integrated hygrostat is in operation, the
device runs continuously. The device can also be
fitted with an external hygrostat connected to a
socket.
The integrated hygrostat is only suitable for a rough
determination of the operating parameters. For ac-
curate room air moisture content readings, you must
use an external, calibrated measuring device.
Water tank
The condensate produced in the device collects in
the water tank. The device is automatically switched
off when the water tank is full.
To empty the water tank, follow the instructions in
Device operation and control
The device cannot be operated with a correctly in-
stalled water tank.
See also
 Intended use
[
28]
14.2.1

Intended use

The device is intended solely for the dehumidifica-
tion of air in closed rooms at atmospheric pressure.
Proper use of the device includes that all operators
have read and understood the operating instructions
and adhering them. Proper use also includes com-
pliance with the specified operating conditions (see
Operating conditions
[
26]). The device must be
checked and serviced at regular intervals.
The device is designed exclusively for industrial and
commercial use.
Any other use is considered improper. Improper use
shall void all warranty cover.
See also
 Technical details
[
39]
14.2.2

Foreseeable misuse

Foreseeable misuse includes:
– Operation in rooms/spaces that are not closed,
or outdoors use
– Operation without adherence to prescribed
clearance distances and operating conditions
14.3

Safety devices

Operating the device without properly installed and
configured safety devices poses a risk to life and
limb. Do not modify, dismantle or disable safety de-
vices. All safety devices must be freely accessible at
all times.
[
32].
EN