Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch PMF 250 CES Originalbetriebsanleitung Seite 15

Vorschau ausblenden Andere Handbücher für PMF 250 CES:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6
OBJ_BUCH-1645-002.book Page 15 Monday, July 23, 2012 8:57 AM
10 Sanding plate
11 Sanding sheet
12 Depth stop
13 Segment saw blade
14 Tool retainer
15 Vacuum hose*
16 Vacuum connection*
17 Fastening screw of the dust extraction*
18 Dust extraction*
19 Felt ring of the dust extraction*
*Accessories shown or described are not part of the standard de-
livery scope of the product. A complete overview of accessories
can be found in our accessories program.
Technical Data
Multi-function tool
Article number
Preselection of orbital stroke
rate
Constant electronic control
Soft starting
Rated power input
Output power
No-load speed n
0
Oscillation angle, left/right
Weight according to
EPTA-Procedure 01/2003
Protection class
The values given are valid for a nominal voltage [U] of 230 V. For differ-
ent voltages and models for specific countries, these values can vary.
Noise/Vibration Information
Measured sound values determined according to EN 60745.
Typically the A-weighted noise levels of the product are:
Sound pressure level 84 dB(A); Sound power level 95 dB(A).
Uncertainty K =3 dB.
Wear hearing protection!
Working without auxiliary handle
Vibration total values a
(triax vector sum) and uncertainty K
h
determined according to EN 60745:
2
Sanding: a
=10 m/s
, K=1.5 m/s
h
Cutting with plunge cut saw blade: a
Cutting with segmental saw blade: a
2
Scraping: a
=12 m/s
, K=1.5 m/s
h
Working with auxiliary handle
Vibration total values a
(triax vector sum) and uncertainty K
h
determined according to EN 60745:
2
2
Sanding: a
=9 m/s
, K=1.5 m/s
h
Cutting with plunge cut saw blade: a
Cutting with segmental saw blade: a
2
Scraping: a
=16 m/s
, K=1.5 m/s
h
Bosch Power Tools
The vibration emission level given in this information sheet
has been measured in accordance with a standardised test
given in EN 60745 and may be used to compare one tool with
another. It may be used for a preliminary assessment of expo-
sure.
The declared vibration emission level represents the main
applications of the tool. However if the tool is used for differ-
ent applications, with different accessories or poorly main-
tained, the vibration emission may differ. This may signifi-
cantly increase the exposure level over the total working
period.
An estimation of the level of exposure to vibration should also
take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may sig-
nificantly reduce the exposure level over the total working
period.
Identify additional safety measures to protect the operator
from the effects of vibration such as: maintain the tool and the
PMF 250 CES
accessories, keep hands warm, organise work patterns.
3 603 A00 6..
Declaration of Conformity
We declare under our sole responsibility that the product
described under "Technical Data" is in conformity with the fol-
lowing standards or standardization documents: EN 60745
according to the provisions of the directives 2011/65/EU,
W
250
2004/108/EC, 2006/42/EC.
W
140
Technical file (2006/42/EC) at:
-1
min
15000–20000
Robert Bosch GmbH, PT/ETM9,
D-70745 Leinfelden-Echterdingen
°
1.4
Dr. Egbert Schneider
Senior Vice President
kg
1.3
Engineering
/II
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
Leinfelden, 29.05.2012
Assembly
Mounting the Auxiliary Handle
Using the auxiliary handle 6 is recommended. It makes work-
ing more easy and comfortable.
Screw the auxiliary handle 6 either at the right or the left side
of the housing into the thread 7.
2
2
2
=13 m/s
, K=2 m/s
h
Changing the Tool
2
2
=14 m/s
, K=3 m/s
h
2
.
2
2
=17 m/s
, K=2 m/s
h
2
2
=18.5 m/s
, K=3 m/s
h
2
.
Helmut Heinzelmann
Head of Product Certification
PT/ETM9
Before any work on the machine itself, pull the mains
plug.
Wear protective gloves when changing application
tools/accessories. Contact with the application tool/
accessoriy can lead to injuries.
English | 15
2 609 006 340 | (23.7.12)

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis