Tandberg Data
Label
Indicator (Left Front Panel)
2.6
6.0
10.0/15.0
20.0
Compress
Density Override
All four right-side or
all left-side indica-
tors
Tandberg DLT4000 Installation Guide
Configuring and Operating the Tandberg DLT4000 Drive
Color
State
Yellow
On
Blinking
Yellow
On
Blinking
Yellow
On (default)
Blinking
Yellow
On (default)
Blinking
Yellow
On
Off
Yellow
On
Off (default)
Blinking
Blinking
Operating Condition
Tape is recorded in 2.6 GB
format.
Tape is recorded in another
density. You selected this
density for a write from BOT.
Tape is recorded in 6.0 GB
format.
Tape is recorded in another
density. You selected this
density for a write from BOT.
Tape is recorded in 10.0/15.0
GB format.
Tape is recorded in another
density. You selected this
density for a write from BOT.
Tape is recorded in 20.0 GB
format.
Tape is recorded in another
density. You selected this
density for a write from BOT.
Compression mode is enabled.
(Compression can be done in
10.0/20.0 GB density only.)
Compression mode is disabled.
You selected a density from the
front panel.
Density to be selected by the
host (automatic).
You are in density selection
mode.
A POST error occurred.
3-15