Herunterladen Inhalt Inhalt Diese Seite drucken

Tandberg Dlt4000 Troubleshooting Chart - TANDBERG DLT4000 Installations-Handbuch

Pc-backup-systeme
Vorschau ausblenden Andere Handbücher für DLT4000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Tandberg Data
2.7.

Tandberg DLT4000 Troubleshooting Chart

If ...
Your system does
not recognize the
Tandberg DLT4000
tabletop drive
Tandberg DLT4000 Installation Guide
Installing and Configuring the Tandberg DLT4000 Drive
Then ...
Your system might not
be configured to see
the SCSI ID
The SCSI ID might not
be unique
The parameters for
your SCSI adapter
might be incorrect
The SCSI signal cable
might be loose
The SCSI terminator
might not be present
or might be loose
The SCSI bus might
not be correctly
terminated
The SCSI terminator
might not be at the end
of the bus, or more
than two terminators
might be present
You should ...
Configure your system to see the ID.
Change the SCSI ID and reconfigure
the system. The new ID is effective
at the next power-on.
Check your SCSI adapter
installation.
Make sure the connector on each
end of the cable is fully seated.
Install the terminator; make sure the
terminator is fully seated.
If the Tandberg DLT4000 tabletop
drive is the last or only device on the
bus, make sure the terminator is
installed on the Tandberg DLT4000
tabletop drive.
If the Tandberg DLT4000 tabletop
drive is not the last or only device on
the bus, check the cable
connections and make sure the
terminator is installed at the end of
the bus.
Be sure to install a terminator at
each end of the bus. One terminator
is usually installed at the system.