CONNECTION OF THE CIRCULATION PUMP,
CLIMATE SYSTEM (GP10)
If the climate system does not already have an external
pump, one can be connected to the accessory card.
Connect the circulation pump (GP10) to AA5-X9:2 (230
V), AA5-X9:1 (N) and X1:3 (PE).
Unit box External
4
3
L
2
N
1
PE
AA5-X9
1
2
3
X1
CONNECTION OF THE REVERSING VALVE
MOTOR (QN19)
Connect the motor (QN19) to AA5-X9:6 (signal), AA5-
X9:5 (N) and AA5-X10:2 (230 V).
9
Unit box External
8
7
9
AA5-X9
8
6
7
5
Black
6
4
Blue
5
3
Brown
4
2
3
1
2
1
-X10
-X10
2
1
AA5-X10

DIP SWITCH

The DIP switch on the accessory card must be set as
follows.
Pool 1
Pool 2
POOL 40 | GB
All manuals and user guides at all-guides.com