Herunterladen Inhalt Inhalt Diese Seite drucken

steute SW868 Montage- Und Anschlussanleitung Seite 5

Funkempfänger 24vac/dc
Inhaltsverzeichnis

Werbung

RF Rx SW868/SW915/SW917/SW922-4W 24VAC/DC
//
Montage- und Anschlussanleitung / Funkempfänger
Mounting and wiring instructions / Wireless receiver
Instructions de montage et de câblage / Récepteur sans fil
Istruzioni di montaggio e collegamento / Ricevitore wireless
Instruções de montagem e instalação / Receptor sem fio
Инструкция по монтажу и подключению / Радио-приемник
English
Safety
Do not use the device in connection with other devices whose direct or
indirect purpose is to ensure life or health, or whose operation may
pose a threat to humans, animals or material assets.
N.B.
The electrical connection may only be carried out by authorised per-
sonnel. Subject to technical modifications. The described products
were developed in order to assume safety functions as part of an entire
plant or machine. It is the responsibility of the manufacturer of a plant
or machine to guarantee the correct general function. steute does not
assume any liability for recommendations made or implied by this de-
scription. New claims for guarantee, warranty or liability cannot be de-
rived from this document beyond the general terms and conditions
of delivery.
Variants
Mat. No.
Variant
1244986
RF Rx SW868 4W 12 VDC Status monitoring
1319798
RF Rx SW868 4W Battery/Status monitoring
In these variants the status monitoring or status and battery monitor-
ing functions are always activated (factory setting of status monitoring
to 10 s).
Start-up
Requirements:
- Device is mounted on DIN rail.
- Conductors for 24 VAC/DC voltage supply are connected.
- A maximum of 40 switches can be taught in parallel.
- The LEDs show the operating states. When the operating voltage has
been provided to the receiver and no switch has been taught in, the
orange LED 1 flashes. When the operating voltage has been provided
to the receiver and switches have already been taught in, the orange
LED 1 is off.
Select operation mode
There are nine different operation modes (see table). They may be se-
lected only after switch-on of the receiver. Operation modes may be
selected during configuration mode only. The relay functions can be
combined with the switching functions.
1. To start the receiver in configuration mode and select an operation
mode: press push-button S1 and keep it pressed. Switch on the sup-
ply voltage. Once the LED MD is blinking: release push-button S1.
Operation mode changes consecutively every 5 s automatically or by
pressing push-button S2. For display of the LEDs: see table.
2. If the desired operation mode is displayed, press the push-button S1
for 1 s. The desired operation mode is now activated. If S1 is not ac-
tuated within 5 s, it is switched to a different operation mode.
Operation
LED 1
mode
Standard
flashes
fast
Relay functions
Standard,
flashes
inverse output
fast
Relay energised
on
Relay energised,
on
inverse output
Switch functions
Logic function
flashes
slowly
Latching
on
function
Wiping
flashes
function
slowly
Additional
functions
Battery
off (LED
monitoring
3 flash-
es)
Status
off (LED
monitoring
4 flash-
es)
Detected errors are additionally indicated by flashing of the
assigned channel LED.
Notice
If only one or both additional functions are activated, no further wire-
less transmitter can be taught in.
Operation mode logic function
- Select logic function. -> LED MD flashes fast.
- Set logic function push-button S2. -> Observe LED display (see table).
- When the desired LED combination is displayed, press push-button
S1 for 1 s.
5 / 28
LED MD
Function
flashes
Relay energised by actua-
fast
tion, relay and switch func-
tions are reset.
on
Upon actuation: relay is de-
energised. Inverse output
signal.
flashes
Relay energised by providing
fast
operating voltage.
on
Relay energised by providing
operating voltage, inverse
output signal.
on
The logic functions OR, AND
or Xor are selectable.
flashes
Latching function/
slowly
Impulse function
flashes
Wiping function. After pre-
slowly
set time: contact de-ener-
gises automatically.
flashes
Relay K3 indicates under-
slowly
voltage of the taught-in and
battery-powered switches/
transmitters.
flashes
Relay K4 indicates status
slowly
error; activates function only
in combination »switch with
status signal«.

Werbung