5.5.5 Sliding the regenerator into
the pipe
4
5
1. Check that the tension cable is posi-
tioned securely on the regenerator be-
fore sliding it in.
2. Slide the regenerator with the filters
that have already been fitted into the
pipe until it approximately reaches the
centre of the wall.
– The regenerator and tension cable
must not touch the fan's impeller.
5.5.6 Installing the fan unit
A
1. Install the fan unit with the wind guard
and front panel (that have already been
fitted) on the wall-mounting frame.
2. Ensure that the contact for the plug
connection has been correctly estab-
lished on the wall-mounting frame.
0020236694_00 recoVAIR Installation and maintenance instructions
B
6 Start-up

6.1 Switching on the product

Applicability: VAR 60/1 D
Use the on/off button to switch on all
of the ventilation units in the ventila-
tion system.
Use the VAZ CPC control or the
VAZ RC remote control to set an
operating mode and the functions.
– See the operating instructions for
the control or for the remote con-
trol.
Applicability: VAR 60/1 DW
Use the on/off button to switch on all
of the ventilation units in the ventila-
tion system.
Use the VAZ CPCW control or the
VAZ RCW remote control to set an
operating mode and the functions.
– See the operating instructions for
the control or for the remote con-
trol.

7 Troubleshooting

Conditions: Ventilation units do not work
Switch off the product.
Ensure that the fan unit is correctly
mounted on the wall-mounting frame
and the contact for the plug connection
has been established.
Conditions: The remote control and MASTER do
not communicate with each other
Shorten the radio link to less than 15 m.
Conditions: Ventilation units only work in night
mode
Ensure that the MASTER is not
covered.