Ordinarily possible over heating due to inappropriate installation is protected by the NTC temperature
control and the latching temperature limiter. If overheating of a carbon heating element occur due to
interlinkage of mounting and installation mistakes, the carbon filaments inside of the quarz tubes will
fuse and safely disconnect the current flow. Even after a mechanical break of the quarz tubes, the carbon
heating spirals will not work any longer. Besides the fin front screen of the SPOT heaters and the glass
ceramic, high temperature resistant front screen of the VISION heaters provide best protection of the
installed carbon heating elements.
Functional description of the NTC temperature control: If the system temperature of the electronical
control exceeds 103°C, the upper heating element will shut off temporary by default to avoid over hea-
ting of the electronical parts. After a short time the heating element will switch on automatically again.
EN
The self-controlled shut off of the heater will take place only, if the heat dissipation inside the device is
inappropriate, if the heat radiation is interfered or if the ambience temperetaure is way too high. Apart
from that the NTC temperature control supports energy safings, if the ambient temperatures are too high
and the highest heating level of the heating unit is not necessary.
Functional description of the latching temperature limiter: If the NTC temperature control is not wor-
king against expectations, the latching temperature limiter will shut down the lower heating element
permanently (two red lights are flashing on the front of the device), until the heater is shut off totally by
hand. After cooling down (warm to the touch) and fixing the inappropriate heat dissipation inside the
device and/or the interferred heat radiation the heater can be switched on again (the two red light on
the front stopped flashing). If the lower heating element shuts down once more (or if the two red lights
continue flashing), a system malfunction or a heat dissipation inside the device or an interference of the
heat radiation or an error in the electrical installation may be the reason. If a system malfunction inside
the device causes the shut down, the heater must be repaired by a professional technician; please con-
tact your dealer immediately. If a wrong cable connection causes the shut down, this has to be checked
and fixed through a professional electrician on the spot.
Installation and connecting regulations with tested and approved luster terminals are part of the deli-
vered equipment.
13. The radiant heater must not be installed directly below a power source/socket. The sides of the unit
must be at least 20 cm from the nearest power source. Sockets/power sources must be freely accessible
at all times and comply with the following specifications: 220–240 V AC ~, 50/60 Hz, 16 A with 16 A fuse.
No other loads may be connected to this power source.
14. The radiant heater must not be installed in rooms where there is high humidity (bathroom, spa, pool
etc.) in close vicinity to bathtubes, showers or pools. The distance to the bathtub or shower must be at
least 100 cm and the distance to the pool at least 200 cm. A person standing in the bathtube, shower or
pool should never reach the switch or controller of the heater. If the HEATSCOPE® is installed in such an
environment with high humidity, the switches or other operating components must be positioned in such
a way that they cannot be touched by persons who are in direct contact with water. When a radiant hea-
ter is installed in a bathroom, the CE standard requires that at least one heating element visibly „glows"
as soon as the unit is switched on.
15. The heater must not be installed nor operated in environments containing chlorine (like inside pool
areas) or salt (like near the coast).
16. Disconnect the radiant heater from the power supply before cleaning it, adjusting the angle or remo-
ving it from the wall/ceiling. Wait until the heating elements are not glowing any more and the housing
MHS Munich Home Systems GmbH · Kramergasse 32 · 82054 Sauerlach · Germany

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis