Communication Objects; Parameters; General - Niko SWISS GARDE 300 Applikationsbeschreibung

Vorschau ausblenden Andere Handbücher für SWISS GARDE 300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2524X/2525XCH

2. COMMUNICATION OBJECTS *

input objects
output objects
Object
Function
0
Output - light (preset dimming)
0
Output - light (switching)
0
Output - light (scene)
1
Input external switch / status - light
(switching)
2
Input external motion - light (switching)
3
Input - light (forced control)
3
Input - light (lock)
4
Output - HVAC (switching)
5
External switch / status - HVAC (switching)
6
External motion - HVAC (switching)
7
Input - HVAC (forced control)
7
Input - HVAC (lock)
8
Threshold switch brightness (switching)
9
Brightness (lux value)
10
AD calibration value
16
Constant light control, switch on/off
17
Constant light control, dimming relative
18
Constant light control, preset dimming
20
Constant light control, forced control
21
Constant light control, scene selection
22
Constant light control, channel 1 - output
23
Constant light control, channel 2 - output
24
Light - standby
* Communication objects program version v2.4

3. PARAMETERS

To set the parameters, the SG360P KNX/KLR RA/EA motion detector should be highlighted in the configuration or operating mode and the command Parameter be selected from the Edit menu item or via the context menu
(right mouse click). The Edit parameter... window will open with multiple tabs.

3.1. General

4
Type of detector
Delay time for forced control mode
EN
link application with
light group actuator
light group actuator.
light group actuator
KNX switch, touch display, logic
Output - light for slave unit (object 0)
• External logic module
KNX switch, touch display, logic module
• Actuators for HVAC devices such as heating, ventilation and air conditioning
• Control of alarm logic modules
• Presence function
KNX switch, touch display, logic
Output HVAC for slave unit (output object 4).
External logic module
KNX switch, touch display, logic
Logic, actuator
Logic, touch display
Read out and then set manually for calibration procedure
KNX switch , logic
4 bit dimming object from KNX switch for ON/OFF, dimming up and down, touch display
Logic module
KNX button, logic
Logic module
Dimming actuator for light group 1
Dimming actuator for light group 2
Switching of standby value sets
The function of the detector is set as a master or slave device
The value "OFF" or a time of 5 min to 9 hrs can be selected in the reset time forced control menu. This parameter defines the time delay for the detector to reset to AUTO
mode, after an OFF or ON command has been executed.
Bit/Byte
1 byte
1 bit
1 bit
1 bit
1 bit
2 bit
1 bit
1 bit
1 bit
2 byte
2 bit
1 bit
1 bit
2 byte
2 byte
1 bit
4 bit
1 byte
1 bit
1 byte
1 byte
1 byte
1 bit
2524X_2525XCH_ETS_description