BSI R65K0-HXX(A) -M _ _ _ _ _ -S92/ST39
MEMS Inclination Sensors with CANopen Output
The CE symbol confirms that our products
comply with the requirements of the current
EU directive.
Validity
These instructions describe the structure, function,
installation and operation of the
BSI R65K0-HXX(A)-M _ _ _ _ _ -S92/ST39 series.
Downloading the user's guide
The user's guide can also be found on the Internet at
www.balluff.com on the product page.
Intended use
The inclination sensor was built to monitor the angle of
inclination in one or two axes.
Inclination sensors are installed for use in, for example,
machines, equipment, devices and systems whose inclina-
tion position has to be determined precisely and set
exactly via connected PLC controllers and motors. Flaw-
less function in accordance with the specifications in the
technical data is ensured only when using original Balluff
accessories, and use of any other components will void
the warranty.
Modifications to the sensor or non-approved use are not
permitted and will result in loss of warranty and void any
liability claims against the manufacturer.
Safety notes
Before commissioning, read the user's guide
carefully!
These sensors must not be used in applications
in which the safety of persons is dependent on
the function of the device (not a safety
component according to EU Machinery
Directive).
Installation and startup are to be performed by trained
technical personnel only.
The operator is responsible for ensuring that local safety
regulations are observed.
In particular, the operator must take measures to ensure
that a defect in the measuring system will not result in
hazards to persons or equipment.
If defects or non-clearable faults in the sensor occur, take it
out of service and secure against unauthorized use.
www.balluff.com
Dimensions
Socket (only at
BSI R65K0-...-ST39)

Electrical connections

Pin
Installation
60
7
46
89
Caution!
Only establish the electrical connection in a
deenergized state.
Signal
1
Shield
2
Operating voltage +
(10...32 V DC)
3
GND / CAN_GND
4
CAN_H
5
CAN_L
Only use shielded cables!
Caution!
Note the alignment of the inclination axis or
axes during installation.
Always install the inclination sensors in a deenergized
state.
The measurement values can be inexact for equipment
that vibrates heavily. Ensure sufficient vibration isolation
or use the version with acceleration compensation.
In highly accelerated systems, the sensor does not
provide exact measurement values (except the version
with acceleration compensation).
Make sure that the installation surface is clean and
level.
For installation, the end of the connector should always
be straight.
Socket (only at
BSI R65K0-...
-ST39)
3
4
5
2
Plug
Socket
1
M12
M12
3
4
4
3
5
5
2
1
1
2
4
3
5
1
2
english