• Connect the 9 V block battery to the battery clip with the correct polarity (note + and -) and insert it
into the battery compartment.
• Replace the battery compartment cover and retighten the screw you undid before.

7. Getting started

CAUTION! Never exceed the max. input values stated.
Switch the multimeter on by twisting the range selector switch [3] to your chosen measurement range.
The multimeter has an auto power OFF function which works as follows:
If the multimeter is not used for approx. 15 minutes, a beep sounds. Another minute later, another
beep sounds and the device switches into sleep mode. Press any button to stop it doing so.
To wake the multimeter up out of sleep mode, turn the range selector switch [3] to a different
measurement range or press any button.
In order to deactivate the auto power OFF function, proceed as follows: When you switch on the
multimeter, press and hold the SELECT button [8]. The
no longer shown on the display [1].
Next time you switch the multimeter on, the auto power OFF function is active again
[1] shows the
You can also switch the multimeter off directly by turning the range selector switch [3] to the "OFF"
position.

7.1 Out of range display

The multimeter has an out-of-range display. If a measured value exceeds the range limit for the
measurement range selected, "0L" is shown on the display [1]. If this happens, remove the measurement
probes [6] from the object you are measuring immediately.

7.2 DC voltage measurement

• Connect the black measurement cable to the COM connection [4] and the red measurement cable
to the
OUT INPUT connection [5].
• Set the range selector switch [3] to the V
• Connect the measurement probes [6] to the object to be measured.
symbol again.
symbol for the auto power OFF function is
position.