Herunterladen Inhalt Inhalt Diese Seite drucken

Sony TRINITRON KV-21CT1B Servicehandbuch Seite 6

Vorschau ausblenden Andere Handbücher für TRINITRON KV-21CT1B:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 128
KV-21CT1B/21CT1U/21CT1E/21CT1K
2. DISPLAY OF
STANDBY (1)
FLASH COUNT
Lamp ON 300ms
Lamp OFF 300ms
3. STOPPING THE
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY (1)
indicator from flashing.
4. SELF-DIAGNOSTIC SCREEN DISPLAY
For errors with symptoms such as "power sometimes shuts off" or "screen sometimes goes off" that cannot be confirmed,
it is possible to bring up past occurrences of failure on the screen for confirmation.
[To Bring Up Screen Test]
In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:
/ Channel 5 / Volume
Display
The following screen will be displayed indicating the error count.
ERROR MENU
2 :
0
3 :
N/A
4 :
0
5 :
1
8 :
0
101 :
N/A
RM-W100
INDICATOR
Lamp OFF 3 sec
INDICATOR FLASH
STANDBY (1)
˘
Note that this differs from entering the service mode (volume [+]).
Numeral "0" means that no fault was detected.
Numeral "1" means the number of a fault occurrence (1 ~ 255).
Diagnostic Item
+B overcurrent
V-Protect
IK (AKB)
HV Protect
* One flash count is not used for self-diagnosis.
/ Power
/ TV
– 6 –
Flash Count*
2 times
4 times
5 times
8 times
STANDBY u indicator