6.9.3.4
Current sensors
List of all current sensors (shunts). Connected current sensors are added to the list automatically. You cannot manually add
a new current sensor. On this list, you can view current readings (amperes) for all connected current sensors. By selecting a
specific sensor, you can view or change its settings.
6.9.3.4.1
Name
Here, you can view or edit the current sensor name.
6.9.3.4.2
Range
Caravan panel shows the current sensor with a graphical representation (horizontal bar), together with the current
numerical value. This value defines the maximum value (amps) for the horizontal bar.
6.9.3.4.3
Reverse current
If you swap the wires on the shunts terminals, the Caravan Panel will show the opposite value of the current. For example,
when discharging, Caravan Panel will show the charge current and vice-versa. In this case, you can use this setting to reverse
the current value. If you set this value to ON, the Caravan Panel will reverse the measured value.