Sensor

Voltage or resistance sensor used to measure the tank level. Here, you can view or select the corresponding sensor. You
can only select sensors that are not already used in a configuration of another device.
6.9.3.2.5

Capacity

Used to set up the full tank capacity.
6.9.3.2.6

Calibration points

Here you can view the list of calibration points for the tank. You can also add new calibration points or remove existing ones.
If you are adding a new tank, at least two calibration points have to be added for a correct configuration. More calibration
points will enable the Caravan Panel to show the tank level more accurately. Up to 11 calibration points can be added.
For each calibration point, the tank fill volume and a corresponding sensor value (resistance or voltage) must be set.
A – fill volume of a tank [liters/gallons]
B – sensor value, resistance [ohms] or voltage [volts]
To add a new calibration point:
Select CALIBRATION POINTS > Add New.
·
Two values will appear on the screen. The value on the left shows the tank fill volume and the value on the right shows the
·
corresponding sensor value (resistance in ohms or voltage). Press
Use arrow buttons to enter the desired tank level in liters or gallons. Press
·
Now the right value (resistance or voltage) turns yellow. A menu pops up, which allows you to select:
·
MEASURED VALUE: Use the current measured value of the selected sensor (resistance or voltage).
INPUT VALUE: By selecting this item, you can manually enter the desired value (resistance or voltage).
to set the tank level. The left value turns yellow.
to confirm the value.
46