Note
The general handling of thermostats in this manual is
also valid for Uponor Smatrix Base Pro X-148 Modbus
RTU.
1―11 Connect the components
1.
Attach the full assembly, or parts of it, to the wall either with a
DIN rail or by using wall screws and plugs.
2.
Connect the actuators.
3.
Connect a thermostat communication cable to the controller,
slave module, and/or the optional star module. Note: Daisy chain
bus topology is recommended.
See section Communications protocol, Page 10 for more
information.
4.
Connect a thermostat communication cable to the thermostat/
timer.
5.
Connect a system bus communication cable in between
controllers and route one cable to the interface. Note: Daisy
chain bus topology is recommended.
See section Communications protocol, Page 10 for more
information.
6.
Connect a system bus communication cable (6.1) and a power
cable (6.2) to the interface.
7.
Check that all wiring is complete and correct:
Actuators
Heating/cooling switch
Circulation pump
8.
Ensure that the 230 V AC compartment of the controller is
closed and the fixing screw is tightened.
9.
Connect optional external sensor (compatible thermostats only)
and set the DIP switch (public thermostat T-143 only).
9
T-143
9 . 1
T-148
T-149
T-146
11.1
3 s
3 s
11.2
11.2
T-148
T-149
T-146
T-143
9 . 2
T-149
11.3
11.4
04
Function
Standard room thermostat
Standard room thermostat together with a floor
temperature sensor
Standard room thermostat, or system device, together
with an outdoor temperature sensor
System device together with a supply temperature
sensor for heating/cooling switch over function
System device where the sensor input is used for
Comfort/ECO switch over function **
Remote sensor
* The thermostat can only be registered as a system device to a
Base PRO system with multiple controllers, if it is registered to
the master controller.
** Closed = ECO
Uponor Smatrix Base PRO
9.4
9 . 1
T-143
ON
DIP
1 2 3 4
9 . 3
9 . 2
11.5
T-148
T-148
T-146
T-149
T-146
11.4
Switch
ON DIP
1 2 3 4
ON DIP
1 2 3 4
ON DIP
1 2 3 4
ON DIP
1 2 3 4
ON DIP
1 2 3 4
ON DIP
1 2 3 4
|
Quick guide
EN
|
7