Troubleshooting / fault rectification
Unit does not switch on
• Please check that the mains cable is correctly seated .
• Please check (if necessary with a suitable measuring device) whet-
her there is voltage for the mains cable at the socket .
• Please check the appliance fuse and the house fuse . Replace the
fuse(s) if necessary .
Modelling light does not work
• Please check whether the modelling light is switched on .
Flash does not fire
• Disconnect the unit from the power supply . Please check that the
flash tube is correctly seated and that the ignition wire is correctly
connected. Never touch the flash tube or the ignition wire with your
bare hand. Use cotton gloves or a microfibre cloth.
• Replace the flash tube if necessary (see page 31).
• Please check whether the overheating mode has been activated
on the unit . In this case, the symbol appears on the LC display .
Please interrupt your work immediately and let the flash unit cool
down until the symbol "OH" on the display disappears . The unit is
then ready for operation again .
Flash does not fire via the photocell (infrared sensor)
• Please check whether the photocell is switched on .
• Please check whether the photocell is covered .