2
Systemübersicht
Timingdiagramm
www.balluff.com
REMOTE
"S" closed
Switch "S"
*
t
rotate
BASE
"Data Valid"
**
t
DAV
BASE
"Signal"
t
depends on the rotating speed.
rotate
Costumers specification: maximum rotating speed of 44rpm and the mounting position
(radius = 600mm) => t
rotate
**t
= 50msec
DAV
"S" open
=1.37s
5