Ref. 1128/44 or
Ref. 1128/45
1. Programming button
2. Calling buttons
3. Panel selection jumper with buttons Ref. 1128/1
or Ref. 1128/2
4. External power 12V~ selector jumper
5. Connector for connecting buttons modules
Ref. 1082/40 and Ref. 1082/41
6. Name tag lighting LED connector
DESCRIPTION OF TERMINAL BOARDS
L1
Bus Line 1st connector
L2
Bus Line 2nd connector
PA
Hall door opener button input (normally open)
SP
Open door sensor contact input (closed with closed door)
GND
Reference earth PA, SP.
~0
Relay power for electrical lock
~12
Relay power for electrical lock
C
Relay exchange electrical lock common contact
NC
Electrical lock relay normally closed contact.
NO
Electrical lock relay normally open contact.
R
Video switching enable signal for video systems
R1
Video power earth

TECHNICAL SPECIFICATIONS

Stand-by consumption:
<6,5mA
Active voice consumption:
<70mA
Relay contact:
2A
Working temperature range:
-10° +50°
Humidity:
5% - 95%
14
2
5
1. Name tag lighting LED connector
2. Calling buttons
3. Connector for button module connection
4. Connector for connecting the previous button
module or door unit module

INSTALLATION

Proceed as follows to install:
1
Ref. 1082/40 or
Ref. 1082/41
2
4
3
The following elements must be considered for correct system construction:
• The surrounding electrical environment.
• The wire type and cross-section area.
• The extension of the system.
SURROUNDING ELECTRICAL ENVIRONMENT
Construct the system respecting the safety standards. Avoid running bus wires (main station side bus and
door phone side bus) near power lines in the building, e.g. staircase lights, lifts, power line risers (230Vac).
A distance of at least 10 cm is recommended.
If wires must be laid near existing power lines, arrange a metallic partition in between, as commonly
employed in telecommunication system construction.
Important: No part of the BIBUS 2nd edition system must be connected to electrical earth.
WIRE TYPE
Use a normal one-pole wire with a suitable cross-section area for electrical connections. Multiple pole wire
must not be used. The main push-button panel side bus and the door phone side bus must run in separate
conduits. Coupler spines (where fi tted) must run in reciprocally separate conduits.
Telephone wire terminals L1 and L2 with a diameter exceeding 0.6 mm (AWG22) can be used for distances
less than 100 metres between calling station and bus coupler, or between bus coupler and most distant door
phone.
DS1072-031
DS1072-031
1
2
3
15