ASSEMBLY OF THE OUTDOOR STATION
The door intercom point is designed for surface mounting.
Preparation
1. Remove the two screws in order to be able to open the casing
on the outdoor station. The casing is also fitted with notches and
projections that connect the upper and lower parts of the casing.
Thus a certain amount of force is necessary in order to separate the
casing parts.
2. Position the drilling template for the outdoor station in a level
location at the intended assembly location (a spirit level is helpful
for this) and attach it with sticky tape.
3. Use the drilling template to drill the attachment holes with a 6mm
drill and insert a dowel into each hole.
4. Now remove the drilling template.
5. Feed the lines through the large hole in the outdoor station and
secure them with 4 screws.
6. Connect the line in accordance with the wiring plan.
7. Attach the front cover and connect the microphone and loudspeaker
cables to the board according to the numbering (1 for microphone,
2 for loudspeaker).
8. Screw the front cover on using both casing screws. Please ensure
that the screws are not tilted as this can damage the thread in the
lower section of the casing.
Adjusting the nameplate
The nameplate covers can simply be levered off to the front with a
slotted screwdriver, as shown in the side view under Fig. A. Write
on the foil with a smudge-proof felt-tip pen or print a name tag*
on your PC and printer.
Insert the lettered foil/paper, replace the nameplate cover and
push the cover into the case with a little force.
* Size of the nameplate:
VISTUS AD-4010: 71 mm x 50 mm
VISTUS AD-4020: 71 mm x 25 mm
VISTUS AD-4030: 71 mm x 15mm
ASSEMBLY OF THE INDOOR STATION
The installation height of the Indoor stations can be selected freely
according to your circumstances.
1. The casing on the indoor station is kept together with notches and
projections. To separate the lower section from the front section,
press a small slotted screwdriver against the snap fastener (B.15)
on the bottom side.
VISTUS AD-400 I-M 210x240 2019 Fin19.indd 15
2. Use the lower section of the casing as an aid to mark the drill
holes. Make sure that you hold the lower section in a horizontal
position for this step.
NOTE: The lower casing section on the indoor station can also be
attached to a hollow wall box. The corresponding attachment holes
are located around the line feed hole. If this does not provide
enough hold then drill more holes and use them to also screw the
indoor station in place.
3. Drill the attachment holes with a 6 mm drill and insert one dowel
in each hole.
4. Feed the lines through the feed hole in the lower casing part
designed for this purpose and screw this down.
5. Attach the lines in accordance with the wiring plan and replace the
front casing section onto the lower casing section. Make sure that
it clicks correctly into place.
CONNECTION
An exact description of where the individual connections and terminals
are located can be found in the figures. The recommended wiring can
be seen in the corresponding wiring plan in the affix.
Connect the lines to the audio, +15V and GND on the outdoor station.
These terminals are also present on the indoor stations and need to be
connected to one another 1:1.
Note on the 2-family version: Each housing unit has its own
connection terminals, which are assigned as follows: Terminals B are for
the lower bell push button, terminals A for the upper bell push button.
Note on the 3-family version: Each residential unit has its own
connection terminals, which are assigned as follows: Terminals C are for
the lower bell push button, terminals B for the middle bell push button,
terminals A for the upper bell push button.
Connecting the door opener
For the connection of the door opener there is a floating NO contact at
the outdoor unit.
1. Via the operating voltage of the outdoor unit
Therefore connection 1 of the door opener is connected to terminal
10, connection 2 of the door opener to ground/GND (for example
terminal 21). Additionally a bridge is required from +15V (for
example A1) to terminal 11.
15