Once the product has been properly assembled, remove the back panel.
Introduce the gas cylinder in the back of the heater with the valve outlet facing outwards.
Screw the correct regulator onto the gas cylinder valve clockwise. Screw it by hand only,
do not use a spanner.
LEAK TEST
This must be carried out in a well-ventilated area, free from any open flames or other sources
of ignition.
1.
With the regulator connected to the cylinder, turn on the gas cylinder valve 1 and 1/2 turns
anti-clockwise.
2.
Brush and clean the connection between the regulator and the cylinder and from the
hose to the gas cylinder valve with a 50:50 solution of detergent and water.
3.
The appearance of bubbles is an indication of a leak.
IF A LEAK IS DETECTED:
1.
Turn off the cylinder valve (clockwise).
2.
Disconnect the regulator from the gas cylinder.
3.
Take the gas cylinder to a cool, outdoor, well-ventilated area.
IF NO LEAK IS DETECTED:
1.
Slightly turn the cylinder to allow the regulator and hose to fit inside the product.
2.
Place the back panel back in its place.
WARNINGS:
Do not use the heater if a leak is found.
Do not use a naked flame for leak testing.
Do not operate any electrical equipment in the presence of a gas leak.