9 | Start-up

In the case of floor assembly, the height of the cable
duct must reach no higher than the lower edge of the
rear venting grille.
8.2

Fusing

Responsibility
– Operating company
Every electrical connection must be adequately fused.
Technical data [see } Chapter 3.2]
WARNING
Faulty/inadequate electrical fuse.
Contact with live parts may cause electric
shock. Risk of fire due to sparks or overload-
ing.
§ Observe applicable local regulations, e.g.
for electrical installation and operation of
the appliances.
§ Observe applicable standards and safety
instructions.
§ Ensure adequate fuse protection.
§ Never operate the appliance without a
residual current circuit breaker.
§ Never operate the appliance without a line
circuit breaker.
§ Never connect more than one appliance to
one fuse.
§ Never connect more than eight lighting
connections to one fuse.
9
Start-up
Responsibility
– Operating company
WARNING
Damage to the electrical system and/or
the refrigerant circuit.
Contact with live parts may cause electric
shock. Flammable refrigerant can escape and
cause an explosive gas/air mixture. Risk of
fire due to sparks or overloading.
§ Do not start up a damaged appliance.
§ Do not connect any damaged parts to the
power supply, e.g. connection cables.
§ Only qualified staff may replace damaged
parts, e.g. connection cables.
§ Observe safety notices and warnings for
appliances with flammable refrigerants
[see } Chapter 2.5.2].
§ In the event of damage to the appliance,
contact the maintenance service immedi-
ately [see } Chapter 11.3.2].
44 / 104
AHT Cooling Systems GmbH | en-US
NOTICE
Property damage caused by incorrect ambient
conditions.
§ Adjust the appliance to the ambient temperature
before start-up.
§ The ambient temperature must not fall below 16°C
(60.8°F).
Start up the appliance
a) Plug in the power plug on the appliance connec-
tion cable [see } Chapter 8.1].
b) For appliances with their own lighting connection,
additionally plug in the power plug of the lighting
connection cable.
The cooling unit starts to operate after a delay of max.
2 minutes.
c) Select desired operating mode [see } Chap-
ter 5.2] [see } Chapter 3.2].
After start-up, it can take 3-4 hours until the desired
temperature is reached.
10

Operation (use)

Only trained operating personnel may operate the ap-
pliance.
WARNING
Damage to the electrical system and/or
the refrigerant circuit.
Contact with live parts may cause electric
shock. Flammable refrigerant can escape and
cause an explosive gas/air mixture. Risk of
fire due to sparks or overloading.
§ Do not allow external forces to act on the
appliance, e.g. careless handling with a lift
truck or floor cleaning machine.
§ Avoid transmitting pulsations and vibra-
tions to the appliance.
§ Observe safety notices and warnings for
appliances with flammable refrigerants
[see } Chapter 2.5.2].
§ If the appliance is damaged or the electri-
cal fuse protection is tripped:
1. Disconnect the appliance.
2. Secure the appliance against restarting.
3. Contact the maintenance service
[see } Chapter 11.3.2].
CAUTION
Glass breakage.
Lacerations to body parts. Impact injury.
§ Check glass elements for damage, e.g.
cracks, breaks. In the event of damage,
contact the maintenance service immedi-
ately [see } Chapter 11.3.2].
§ Check for closed lids.
§ Do not apply any load to the lids.
§ Do not climb onto or into the appliance.
440195_1_0521