WARNING
Connect the appliance to the power
supply.
Contact with live parts may cause electric
shock. Risk of fire due to sparks or overload-
ing.
§ Only qualified staff may carry out work on
the electrical system.
§ Note and adhere to the following before
connecting to the power supply:
- Applicable local electrical safety regula-
tions.
- Applicable standards and safety instruc-
tions.
- Information on the rating plate
[see } Chapter 3.2.1].
§ Do not connect a damaged appliance or
damaged parts (such as connection ca-
bles) to the power supply.
§ Only qualified staff may replace damaged
parts, e.g. connection cables.
§ Do not squeeze or bend connection ca-
bles.
§ Adhere to minimum requirements for con-
nection cables [see } Chapter 3.2].
§ Fuse the appliance in accordance with the
applicable regulations and legislation, as
well as the AHT specifications
[see } Chapter 8.2].
§ Connect the appliance only to a mains cir-
cuit with protective grounding.
§ Do not use extension cords or multiple
socket strips.
§ Do not damage concealed electrical
parts. Do not drill holes in the appliance
and do not carry out any other work on the
appliance.
NOTICE
Material and property damage caused by non-
AHT-approved deviations (voltage, frequency)
in the operating company's electrical network.
§ The manufacturer is not responsible for damage to
the operating company's electrical equipment or
any subsequent related damage.
Material damage due to faulty electrical con-
nection.
§ Load shedding or appliance shutdowns are not
permitted.
§ A continuous power supply is required.

Appliance connection

There is a tag with a snowflake at the end of
the connection cable.
The appliance connection cable is used to supply
power to the cooling system.
440195_1_0521
NOTICE
Property damage caused by an interruption to
the power supply.
Failure of the cooling system.
§ Do not connect the appliance connection cable to
the power supply for market light.
Lighting connection cable
There is a tag with a lamp symbol at the end
of the connection cable.
The lighting connection cable makes it possible to
switch the appliance lighting together with the market
lighting (energy savings).
Combined unit/lighting connection cable
No labeling flag.
The combined device/light connecting cable is used
for the common supply of the cooling and lighting.
NOTICE
Property damage caused by an interruption to
the power supply.
Failure of the cooling system.
§ Connect the power plug of the combined device/
light connection cable to a power supply that is
permanently supplied with voltage.
Unit with IEC-Box
Unit can be equipped with an IEC-Box.
Connection cable is connected to the IEC-Box by a
plugged connection cable.
WARNING
Faulty electrical connection on the IEC
-Box.
Contact with live parts may cause electric
shock. Risk of fire due to sparks or overload-
ing.
§ The bracket of the IEC-Box must be fixed
correctly and secured by the screw holder.
1
Fig. 13: IEC-Box (1), plugged connection cable light (2) unit
(3), bracket (4), screw holder (5)
AHT recommends the use of a cable duct with sockets
installed or set up in it.
Setup and installation | 8
2
3
4
5
43 / 104

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis