This unit includes an internal regulator which stabilizes the gas pressure and improves grill performance. This
regulator cannot be adjusted. There is a pressure tap located on the side of the regulator. It can be used by
a qualified service person when servicing the grill to determine if the regulator is functioning properly. The
screw within the pressure tap must always be kept tight, except when performing a pressure test on the
regulator (qualified service personnel only).
Electrical Precautions
!
WARNING!
death.
• 230 - 240V / AC - 50HZ – 0.4A.
• To protect against electric shock, do not immerse cord or plugs in water or other liquid.
• Unplug from the outlet when not in use and before cleaning. Allow to cool before putting on or taking off
parts.
• Do not operate any outdoor cooking gas appliance with a damaged cord, plug, or after the appliance
malfunctions or has been damaged in any manner. Contact the manufacturer for repair.
• If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
• Do not let the cord hang over the edge of a table or touch hot surfaces.
• Do not use an outdoor cooking gas appliance for purposes other than intended.
• When connecting, first connect plug to the outdoor cooking gas appliance then plug appliance into
the outlet.
• Use only a Ground Fault Interrupter (GFI) protected circuit with this outdoor cooking gas appliance.
• Never remove the grounding plug or use with an adapter of 2 prongs.
• Use only extension cords with a 3 prong grounding plug, rated for the power of the equipment, and
approved for outdoor use with a W-A marking.
Leak Testing Instructions
!
WARNING!
of the gas system is replaced.
WARNING!
!
in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, damage to
property, serious bodily injury, or death.
Leak testing: This must be done before initial use, annually, and whenever any gas components are replaced or
serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak Testing Diagram
for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one recommended
by the Napoleon Customer Solutions department and have the grill inspected by a certified gas installer.
STOP
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill inspected
by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
N415-0539CE-GB-DE Jul 14.20
Failure to follow these instructions could result in property damage, personal injury or
A leak test must be performed annually and each time a cylinder is hooked up or if a part
Never use an open flame to check for gas leaks. Be certain no sparks or open flames are