Herunterladen Inhalt Inhalt Diese Seite drucken

Miele PFD 104 SCVi Installationsplan Seite 15

Vorschau ausblenden Andere Handbücher für PFD 104 SCVi:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Drain
External dispens-
ing
The dishwasher drain hose should be connected to a separate on-site
drainage system for the dishwasher only. If a separate connection is
not available, we recommend connecting the hose to a dual-chamber
siphon.
If the hose is to be fitted directly to the drainage system on site, use
the hose clip supplied with the dishwasher.
The on-site connector for the drain hose can be adapted to different
hose diameters. If the connector extends more than 30 mm into the
drain hose, it must be shortened. Otherwise, the drain hose can be-
come blocked.
Lay the drain hose so that it does not kink and is not being subjec-
ted to pressure or tension.
If the on-site drain connection is situated lower than the guide path
for the lower basket rollers in the open door, a siphoning effect dur-
ing a programme can cause the wash cabinet to empty itself of wa-
ter.
In this case, lay the drain hose with a bend in it so that its highest
point is at least level with the guide path for the lower basket rollers.
An external dispensing module for liquid cleaning agents can be con-
nected to the back of the dishwasher.
The dispensing module is available as an optional accessory and is
supplied with installation instructions.
en - Installation notes
15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis