42
• Disconnect the connecting cable from the
power supply.
• Press down the locking button of the installed plug
and remove the plug from the control module.
• Observe the terminal assignment (PE, N, L).
• Connect the existing device plug to the plug
connection (11) of the control module.
7 Commissioning
Commissioning only by qualified technicians.
7.1
Venting
• Fill and vent the system correctly.
If the pump does not vent automatically:
• Activate the pump venting function via the operating
button: press and hold for 3 seconds, then release.
The pump venting function is initiated and
lasts 10 minutes.
The top and bottom LED rows flash in turn at 1 second
intervals.
• To cancel, press and hold the operating button
for 3 seconds.
NOTICE
After venting, the LED display shows the previ -
ously set values of the pump.