Herunterladen Inhalt Inhalt Diese Seite drucken

PeakTech 4120 Bedienungsanleitung Seite 31

4 in 1 universal system
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Function
Range
400 mV
DC Voltage
4 V
40 V
400 V
1000 V
400 mV
AC Voltage
4 V
40 V
400 V
750 V
400 µA
DC Current
4 mA
40 mA
400 mA
20 A
400 µA
AC Current
4 mA
40 mA
400 mA
20 A
400 Ω
Resistance
4 kΩ
40 kΩ
400 kΩ
4 MΩ
40 MΩ
Test current ≤ 1 mA
Diode Test
Continuity Test
Buzzer sounds when voltage is less than 80 mV at test current, 3 mA max. (Resistance of <
40 Ω)
Logic Test
Three Logic-Level (Rdy, Hi, ----, Lo)
6.4.3. Features
*
Computer Interface & Software - let you interface the meter with your PC-compatible computer so you can log
measurements.
*
Dual-Display - allows the meter to show one primary + two secondary readings simultaneously on the LED.
Input Range Selection
AC Voltage
Logic
*
Overload and Transient Protection - helps protect the meter from accidental overload on most ranges. "OL" is
displayed, when an input is too excess to display.
*
Min./Max/Data-Hold - let you keep a readings of minimum, maximum and captured value on the on the sub-
display, while showing the present readings on the main-display.
*
Range-Hold - sets the meter from auto-range to manual-range mode except capacitance position. In the manual-
range mode, each you press UP DOWN keys, the range and the input range annunciator increment and/or
decrements, and a new value is displayed.
*
Relative Offset - displays the difference between the stored value and subsequent readings. To set the reference
value, follow these steps:
1.)
Set the function mode at REL mode.
2.)
Store the polarity, values and range of the reference value you desire by pressing the UP DOWN keys
and SET/RESET key by turns.
3.)
Press SET/RESET key for final setting. Then your meter will be set in the manual-range automatically. In
this mode, the total range of relative offset is 39999 counts.
Accuracy
± 0,06% + 3 dgt.
± 0,1% + 5 dgt.
± 0,8% + 10 dgt.
(40 Hz ~ 10 kHz)
± 5% + 15 dgt.
(10 kHz ~ 50 kHz)
± 0,8% + 10 dgt.
(40 Hz ~ 5 kHz)
± 5% + 15 dgt.
(5 kHz ~ 20 kHz)
± 1,0% + 10 dgt.
(40 Hz ~ 1 kHz)
± 5,0% + 15 dgt.
(1 kHz ~ 3 kHz)
± 0,3% + 3 dgt.
± 0,5% + 5 dgt.
± 1,2% + 10 dgt.
(40 Hz ~ 1 kHz)
± 1,5% + 10 dgt.
(40 Hz ~ 1 kHz)
± 1,8% + 15 dgt.
(40 Hz ~ 1 kHz)
± 0,2% + 10 dgt.
± 0,15% + 5 dgt.
± 0,5% + 10 dgt.
Main Display
AC Voltage
HI/LO
-30-
Resolution
Remark
0,01 mV
manual
0,1 mV
1 mV
10 mV
0,1 V
manual
0,01 mV
True RMS
0,1 mV
1 mV
True RMS
10 mV
0,1 V
0,01 µA
0,1 µA
1 µA
10 µA
1 mA
0,01 µA
0,1 µA
True RMS
1 µA
10 µA
1 mA
0,01 Ω
0,1 Ω
1 Ω
10 Ω
100 Ω
1 kΩ
Secondary display
dB(m) / Hz
DC Voltage

Werbung

Inhaltsverzeichnis
loading