Use only the specified fuses for the instrument, as follows:
*
Power line fuse:
Shape:
Type:
*
DMM ampere fuses:
*
Pay your attention to Warning-signs printed on the instrument
The user should refer to the operation manual to protect the instrument against damage.
Dangerous voltage exists.
Ground (Earth terminal)
Indicates protection class II, double insulation
CAT II
Overvoltage Category II
*
Safety:
*
Altitude:
*
Temperature:
*
Operating Temperature:
*
Storage Temperature:
*
Pollution degree:

5. Installation

5.1. Unpacking and inspection
Every care is taken in the choice of packing materials to ensure that your equipment will reach you in perfect
condition.
Unpack the equipment and check for external damage to the case, sockets, keys etc. If damage is found, notify the
carrier and your sales representative immediately.
The standard accessories supplied with the instrument are as described in the Section 1.
5.2. Preparation for Operation
Under no circumstances should users touch any of the front terminals, unless the are first assured that no dangerous
voltage is present.
Power Input
The recess power input plug, power fuse and line voltage indicator are contained in an integral module in the rear
panel.
Power cable
The detachable supply cable, comprising of 3-core PVC cable permanently moulded to a fully-shrouded 3-pin socket,
fits in the power input plug recess and should be fitted fully.
The supply lead should be connected to a grounded AC power receptacle ensuring that the ground lead is
connected, to avoid electrical shock.
Line voltage
®
The PeakTech
4120 is operative within the line voltage ranges 110/120/220/240 V AC ± 10 %, 50/60 Hz, for F/G,
F/C and DPS. Adjust the line voltage selector, suitable for your line supply power.
The DMM section of the instrument is powered by a single 9 Volt adaptor (9 V, 500 mA Center Positive Type).
Bench Mounting
This instrument is fitted with four rubber feet. It is intended to stand flat on a bench, located at least 30 cm of free
space at the rear.
In addition, 2 plastic tilt-stand are provided next to the front rubber feet, to facilitate the viewing angle of the
instrument from the bench level.
3 A/220 V or 240 V AC; 5 A/100 V or 120 V AC; 50/60 Hz
5 ∅ x 20 mm
Slow-blow
400 mA AC/DC Ranges: F 800 mA/250 V; Type: Fast-blow
20 A AC/DC ranges: S 15 A/250 V; Type: Slow-blow
Shape: 6 ∅ x 32 mm
EN 61010-031:2002
max. 2000 m
5°C to 40°C, < 80% R. H.
10°C to 40°C
-10°C to 50°C
II